Rated input: 10KW, 12KW,
Rated hot water output: 5L, 6L (25 centigrade temperature rising);
Gas type: LPG, NG, Town Gas
Rated gas pressure: 2800 Pa (LPG), 2000 Pa ( NG), 1000 Pa (Town gas);
Ignition way: automatic impulse ignition by battery power or electric transformer power;
Diameter of chimney: 5 L- 8 L: 90mm,
Water pressure: 0.015 - 0.8 MPa
Diameter of gas connector: LPG: 9.5mm, NG: 12-15mm
Diameter of cold water connector: G1/2"
Diameter of hot water connector: G1/2"
Product Description
Automatic Ignition by battery or electric transformer power;
Gas Exhaust Type: Flue duct type;
Summer & winter switch for choice;
Over-heat protection device; Unexpected flameout protection device
Low start water pressure;
Water pressure stabilizing design;
20 minutes cut-off device
Water over high pressure protection device;
ODS system for choice;
Over freezing protection device;
Super low water pressure starting design